Logimove Operation Manual - S15,S20-Web - REV05
3.1.1 - S15 - Led Fault Indicator Diagnostics Error Message LED Blinks Explanation
Possible Cause
The controller detects excessive current, Check whether there is a short circuit in the motor phase line. power off and restart. The controller temperature exceeds 95 °C, The controller works continuously under a high load, or the ambient temperature is too high, power off and restart. The supply voltage is below 17V Power supply battery under voltage, power off and restart. The controller detected an over voltage Check whether the power supply voltage is normal. Power off and restart. Emergency reverse switch failure Before power-on, the Emergency reverse switch be engaged, Release the Emergency reverse switch and power on again. INTERLOCK failure before power-on, the interlock switch be engaged, and the reset the tiller and powered on again Opening of electromagnetic brake is abnormal. Electromagnetic brake controller circuit failure, replace the controller. The electromagnetic brake shuts down abnormally. Electromagnetic brake wiring is not reliable, or the drive circuit fault, power off restart Main relay short circuit Main relay drive circuit failure
Over Current
(1,1)
Over Temperature
(1,2)
Under Voltage
(1,4)
Over Voltage
(1,5)
Emergency reverse switch
(2,2)
Main_Short Main_DRI
(2,3) (2,4)
Interlock
(3,1)
Brake
(3,2)
Brake
(3,2)
Pre-Charge
The Pre-charge circuit is abnormal
(3,3)
HPD failure. Before power-on, the accelerator be activated. Release the accelerator and power on the device again.
HPD
(3,5)
Current Sensor
The current circuit is abnormal MOS device damage EEPROM failure or fault. The motor did not connect
(4,1)
MOS
(4,2) (4,3) (4,4) (4,5)
EEPROM Fault Motor Open Temp Sensor
The temperature sensor is disconnected or short-circuited. The emergency stop button being pressed was detected. SRO failure. Before power-on, the lift button be pressed. After the fault is show, walking is not affected, but the lifting is prohibited Release the lift button and power on the device again.
EMCY STOP
(5,1)
SRO
(5,2)
Notice *LED ON: When there is no failure, the LED indicator is on. *LED OFF: The controller is not powered on.