3.1.2 - S20 - Led Fault Indicator Diagnostics Error Message LED Blinks Explanation

Possible Cause

Severe Undervoltage / Undervoltage Cutback Severe Undervoltage / Undervoltage Cutback Over Temperature “Motor Temp Sensor/Hot Cutback” Control Low Temp Throttle/Hpd Sequencing Main Contactor Or Main Driver Fault/ Precharge Failed Encoder / Stall Detected Motor Open Embrake Driver Fault Embrake Failed To Set” EMER REV HPD/EMR SRO Handle Fault

Capacitor bank voltage dropped below the Severe Undervoltage limit;Capacitor bank voltage dropped below the Undervoltage limit with the FET bridge enabled Capacitor bank voltage exceeded the Severe Overvoltage limit;Capacitor bank voltage exceeded the Overvoltage limit with the FET bridge enabled The controller temperature exceeds 75 °C, The controller works continuously under a high load, or the ambient temperature is too high, power off and restart. Motor thermistor input is at the voltage rail(0 or 10V);Motor temperature is at or above the Temperature Hot parameter setting The controller temperature is below -40 °C, “Throttle input is out of range;HPD(High Pedal Disable) or sequencing fault caused by incorrect sequence of KSI, interlock, direction and throttle inputs” “Just prior to the main contactor closing, the capacitor bank voltage (B+ connection terminal) was loaded for a short time and the voltage did not discharge;With the main contactor commanded closed, the capacitor bank voltage (B+ connection terminal) did not charge to B+;Main Contactor driver is either open or shorted;Controller failed to precharge” Motor encoder phase failure detected; No motor encoder movement detected Motor Phase U, V, or W detected open

(1,2)

(1,3)

(1,4)

(1,5)

(1,6)

(2,1)

(2,2)

(2,3)

(2,4)

(2,5) (2,6)

Electromagnetic brake driver is either short

(3,1)

Electromagnetic brake driver is either open “At the conclusion of emergency Reverse,the fault was set because various inputs were not returned to nutral;The EMR switches are turned on before KSI”

(4,2)

Notice *LED ON: When there is no failure, the LED indicator is on. *LED OFF: The controller is not powered on.

Logimove Fully Electric Pallet Jack 33